logo
Produk
rincian produk
Rumah > Produk >
PSC1-C-10-SDM1-FB2 10A Single Contact Interlock IP67 SS Modular Heavy Duty Flange Guard

PSC1-C-10-SDM1-FB2 10A Single Contact Interlock IP67 SS Modular Heavy Duty Flange Guard

MOQ: 1
Harga: USD 100-10000/Piece
kemasan standar: 50*50*50mm
Periode pengiriman: 3-7
Cara Pembayaran: T/T
Kapasitas pasokan: 1/potong dalam stok
Informasi Rinci
Tempat asal
JERMAN
Nama merek
Schmersal
Sertifikasi
3C
Nomor model
PSC1-C-10-SDM1-FB2
sertifikasi:
CE, RoHS
Jangkauan Tegangan Masuk:
0-10V
Kepekaan:
0,1°C, 0,1°F
Paket:
Paket
Protokol komunikasi:
MODBUS TCP
LAYANAN:
Layanan Satu-Stop
Kualitas:
100% Asli 100% Merk
Tipe IO:
In&out digital
Menyoroti:

SS Modular Heavy Duty Flange Guard

,

Single Contact Interlock IP67

,

10A Single Contact Interlock

Deskripsi Produk

1. Product Overview

The Schmersal PSC1-C-10-SDM1-FB2 represents a fully integrated safety solution combining ​10-meter emergency stop cabling (C-10)​​ with the ​SDM1 diagnostic monitoring unit​ and ​FB2 dual-channel control unit. This system delivers SIL 3/PL e compliant emergency stopping with predictive maintenance capabilities for critical infrastructure. The FB2 unit features force-guided relays in an IP66-rated zinc housing, while the SDM1 adds real-time cable integrity analytics through integrated microprocessors. Stainless steel tension cables with polyurethane sheathing (UV-resistant RAL 1023 yellow) withstand oils, chemicals, and temperature extremes (-30°C to +80°C). Designed for kilometer-scale installations, it supports cascading configurations while maintaining <100ms stop response times. Continuous monitoring detects micro-fractures, elongation, and contact degradation before failures occur.

2. Key Technical Parameters

  • Cable System: 10m Ø4mm AISI 316L core with PUR sheath, 70-180N adjustable tension
  • Safety Ratings: ISO 13849-1 PL e (Cat. 4), IEC 62061 SIL 3
  • Electrical:
    • Voltage: 24V DC to 230V AC ±10% (50/60Hz)
    • Safety Outputs: 2 NC contacts (10A/250V AC)
    • Diagnostic Outputs: 3 semiconductor channels (cable health/contact status/system fault)
  • Monitoring Resolution:
    • Cable elongation detection: ±0.5mm
    • Strand break detection: >15% resistance change
  • Environmental: IP66 (FB2)/IP69K (cable glands), -30°C to +80°C, 100m/s² vibration immunity
  • Response: <100ms activation time, 500ms diagnostic scan cycle
  • Connections: M20 entries with screw terminals (max 2.5mm²)

3. Primary Applications and Use Cases

This system is engineered for extreme environments where failure prevention is critical:

  • Mining conveyors: Monitoring multi-kilometer runs with predictive cable replacement alerts
  • Steel hot-rolling mills: Emergency stops along 200°C casting lines with thermal compensation
  • Chemical tank farms: Perimeter protection in corrosive vapor zones
  • Port loading arms: Providing emergency stops across articulating marine structures
  • Airport baggage systems: Curved conveyor networks requiring elongation compensation
  • Automotive test tracks: High-vibration emergency stops along robotic vehicle pathways
  • Power plant coal handlers: Emergency trip systems in combustible dust environments
  • Wastewater treatment: Cable systems resisting H₂S corrosion with ATEX compliance

4. Product Advantages and Functional Benefits

  • Predictive Safety Analytics: SDM1 detects cable fatigue 6-8 weeks before failure
  • Zero False Trips: Temperature-compensated tensioning (±0.05N/°C)
  • Lifecycle Optimization: 60% cable lifespan extension through wear-based replacement
  • Cyber-Resistant Design: Physical-only reset prevents remote manipulation
  • Maintenance Efficiency:
    • Automatic tension logs via IO-Link (optional)
    • Quick-release cable splices for <10min segment replacement
  • Harsh Environment Resilience:
    • Salt spray testing >1,000hrs (ISO 9227)
    • Hydrocarbon-resistant PUR sheath
  • Compliance Simplified: Pre-certified templates for ISO 13850, ANSI B11.19, IEC 62061
  • Redundancy Architecture: FB2 maintains safety function during single-component failure
  • Global Certification: ATEX/IECEx Zone 21, UL Class I Div 2, SIL 3 TÜV report included

5. Core Functionality and Diagnostic Integration

Operation merges mechanical safety with Industry 4.0 diagnostics:
Safety Activation:​

  1. Cable pull (≥70N) mechanically disengages FB2's spring-loaded latch
  2. Force-guided contacts positively open within 100ms (Category 0 stop)
    Diagnostic Oversight (SDM1):​
  • Continuous Cable Monitoring:
    • Micro-Ohm resistance measurement detects strand fractures
    • Laser-engraved fiducials track sheath elongation with 0.5mm resolution
  • Contact Surveillance:
    • Redundancy checks validate NC contact separation distance (>0.5mm)
    • Current monitoring detects contact welding precursors
  • Fault Management:​
    • Stage 1 alert (NO output): 15% cable elongation
    • Stage 2 lockout (NC output): Contact welding detected
    • Event logging: Stores last 20 faults with timestamps
      Reset Protocol:​
  1. Physical key turn at FB2 unit
  2. SDM1 validation:
    a) Cable tension within 5% of calibration
    b) Contact resistance <50mΩ
  3. PLC confirmation via diagnostic handshake

 

 

 

 

Parameter Category Specification Details
Product Type Hybrid Programmable Safety Controller
Series PSC1 (Modular Safety System)
Model Code Breakdown PSC1-C-10-SDM1-FB2 =
• PSC1: Base Unit
• C: 24V DC
• 10: 10 Inputs
• SDM1: Safety Door Monitor
• FB2: Enhanced Function Block
Safety Standards EN ISO 13849-1, EN IEC 62061, IEC 61508
Performance Level (PL) PL e (Category 4)
Safety Integrity Level SIL 3 (IEC 62061/61508)
Core Functionality Integrated safety door monitoring + muting/locking logic
Input Channels 10 Smart Inputs:
• 4x Door position (OSSD/contact)
• 2x Lock status
• 2x Muting sensors
• 2x External commands (E-stop/reset)
Output Channels 6 Safety Outputs:
• 2x Force-guided relays (5A @ 230V AC)
• 2x Lock control (2A @ 24V DC)
• 1x Muting lamp
• 1x Semiconductor status
Hybrid Logic Features SDM1 + FB2 Combined:
• Multi-door sequencing
• Guard locking w/ position verify
• Muting sequences (ISO 13855)
• Time-delayed unlocking (0–600s)
• Cross-zone access control
Voltage Supply 24V DC (20.4–28.8V DC)
Power Consumption ≤ 8W (max with active loads)
Response Times • 35 ms (door status)
• 100 ms (muting)
• 200 ms (lock release)
Safety Functions • Door position monitoring
• Lock engagement verification
• Material flow muting
• Restart interlock
• Standstill detection
Diagnostic Capabilities • Per-function status LEDs
• Event logging (20 faults)
• Real-time muting counter
• Lock cycle monitoring
Enclosure Rating IP20 (Control cabinet)
Mounting DIN-rail (35mm)
Operating Temperature -10°C to +55°C
Connection Type Spring-cage terminals (1.5 mm²)
Certifications CE, UL 508, TÜV Nord, UKCA, EAC
Status Indicators • RGB system status LED
• Door/lock/muting icons
• Input/output state lights
Key Innovations • Simultaneous door/muting control
• Dynamic zone locking
• Machine state-based unlocking
Compatible Devices PSENcode, PSENmlock, SD series, PSENopt muting sensors
Typical Applications Automotive body shops, food processing lines, robotic palletizing systems

 

 

 

 

 

 

 

 

Packaging & Shipping

 

PSC1-C-10-SDM1-FB2 10A Single Contact Interlock IP67 SS Modular Heavy Duty Flange Guard 0

 

Company Information
Xiamen ZhiCheng Automation Technology Co., Ltdit is a leading global supplier of control system components. We specialize in control systems and drives.


With many years of experience in the industrial sector, we consistently deliver the highest quality of spare parts.which make sure that all this jobs are

 

perfectly.

 

PSC1-C-10-SDM1-FB2 10A Single Contact Interlock IP67 SS Modular Heavy Duty Flange Guard 1

 

we are major in PLC,Sensors,HIM,Transmitters.


Best Supply Brands As Following:1)Bently nevada.2)+GF+.3)Rosemount.4)ABB.5)Allen-Bradley.6)Foxobro.Good working environment, perfect team, sincere cooperation →→ Achieve u and our success !!!

 

PSC1-C-10-SDM1-FB2 10A Single Contact Interlock IP67 SS Modular Heavy Duty Flange Guard 2

Produk
rincian produk
PSC1-C-10-SDM1-FB2 10A Single Contact Interlock IP67 SS Modular Heavy Duty Flange Guard
MOQ: 1
Harga: USD 100-10000/Piece
kemasan standar: 50*50*50mm
Periode pengiriman: 3-7
Cara Pembayaran: T/T
Kapasitas pasokan: 1/potong dalam stok
Informasi Rinci
Tempat asal
JERMAN
Nama merek
Schmersal
Sertifikasi
3C
Nomor model
PSC1-C-10-SDM1-FB2
sertifikasi:
CE, RoHS
Jangkauan Tegangan Masuk:
0-10V
Kepekaan:
0,1°C, 0,1°F
Paket:
Paket
Protokol komunikasi:
MODBUS TCP
LAYANAN:
Layanan Satu-Stop
Kualitas:
100% Asli 100% Merk
Tipe IO:
In&out digital
Kuantitas min Order:
1
Harga:
USD 100-10000/Piece
Kemasan rincian:
50*50*50mm
Waktu pengiriman:
3-7
Syarat-syarat pembayaran:
T/T
Menyediakan kemampuan:
1/potong dalam stok
Menyoroti

SS Modular Heavy Duty Flange Guard

,

Single Contact Interlock IP67

,

10A Single Contact Interlock

Deskripsi Produk

1. Product Overview

The Schmersal PSC1-C-10-SDM1-FB2 represents a fully integrated safety solution combining ​10-meter emergency stop cabling (C-10)​​ with the ​SDM1 diagnostic monitoring unit​ and ​FB2 dual-channel control unit. This system delivers SIL 3/PL e compliant emergency stopping with predictive maintenance capabilities for critical infrastructure. The FB2 unit features force-guided relays in an IP66-rated zinc housing, while the SDM1 adds real-time cable integrity analytics through integrated microprocessors. Stainless steel tension cables with polyurethane sheathing (UV-resistant RAL 1023 yellow) withstand oils, chemicals, and temperature extremes (-30°C to +80°C). Designed for kilometer-scale installations, it supports cascading configurations while maintaining <100ms stop response times. Continuous monitoring detects micro-fractures, elongation, and contact degradation before failures occur.

2. Key Technical Parameters

  • Cable System: 10m Ø4mm AISI 316L core with PUR sheath, 70-180N adjustable tension
  • Safety Ratings: ISO 13849-1 PL e (Cat. 4), IEC 62061 SIL 3
  • Electrical:
    • Voltage: 24V DC to 230V AC ±10% (50/60Hz)
    • Safety Outputs: 2 NC contacts (10A/250V AC)
    • Diagnostic Outputs: 3 semiconductor channels (cable health/contact status/system fault)
  • Monitoring Resolution:
    • Cable elongation detection: ±0.5mm
    • Strand break detection: >15% resistance change
  • Environmental: IP66 (FB2)/IP69K (cable glands), -30°C to +80°C, 100m/s² vibration immunity
  • Response: <100ms activation time, 500ms diagnostic scan cycle
  • Connections: M20 entries with screw terminals (max 2.5mm²)

3. Primary Applications and Use Cases

This system is engineered for extreme environments where failure prevention is critical:

  • Mining conveyors: Monitoring multi-kilometer runs with predictive cable replacement alerts
  • Steel hot-rolling mills: Emergency stops along 200°C casting lines with thermal compensation
  • Chemical tank farms: Perimeter protection in corrosive vapor zones
  • Port loading arms: Providing emergency stops across articulating marine structures
  • Airport baggage systems: Curved conveyor networks requiring elongation compensation
  • Automotive test tracks: High-vibration emergency stops along robotic vehicle pathways
  • Power plant coal handlers: Emergency trip systems in combustible dust environments
  • Wastewater treatment: Cable systems resisting H₂S corrosion with ATEX compliance

4. Product Advantages and Functional Benefits

  • Predictive Safety Analytics: SDM1 detects cable fatigue 6-8 weeks before failure
  • Zero False Trips: Temperature-compensated tensioning (±0.05N/°C)
  • Lifecycle Optimization: 60% cable lifespan extension through wear-based replacement
  • Cyber-Resistant Design: Physical-only reset prevents remote manipulation
  • Maintenance Efficiency:
    • Automatic tension logs via IO-Link (optional)
    • Quick-release cable splices for <10min segment replacement
  • Harsh Environment Resilience:
    • Salt spray testing >1,000hrs (ISO 9227)
    • Hydrocarbon-resistant PUR sheath
  • Compliance Simplified: Pre-certified templates for ISO 13850, ANSI B11.19, IEC 62061
  • Redundancy Architecture: FB2 maintains safety function during single-component failure
  • Global Certification: ATEX/IECEx Zone 21, UL Class I Div 2, SIL 3 TÜV report included

5. Core Functionality and Diagnostic Integration

Operation merges mechanical safety with Industry 4.0 diagnostics:
Safety Activation:​

  1. Cable pull (≥70N) mechanically disengages FB2's spring-loaded latch
  2. Force-guided contacts positively open within 100ms (Category 0 stop)
    Diagnostic Oversight (SDM1):​
  • Continuous Cable Monitoring:
    • Micro-Ohm resistance measurement detects strand fractures
    • Laser-engraved fiducials track sheath elongation with 0.5mm resolution
  • Contact Surveillance:
    • Redundancy checks validate NC contact separation distance (>0.5mm)
    • Current monitoring detects contact welding precursors
  • Fault Management:​
    • Stage 1 alert (NO output): 15% cable elongation
    • Stage 2 lockout (NC output): Contact welding detected
    • Event logging: Stores last 20 faults with timestamps
      Reset Protocol:​
  1. Physical key turn at FB2 unit
  2. SDM1 validation:
    a) Cable tension within 5% of calibration
    b) Contact resistance <50mΩ
  3. PLC confirmation via diagnostic handshake

 

 

 

 

Parameter Category Specification Details
Product Type Hybrid Programmable Safety Controller
Series PSC1 (Modular Safety System)
Model Code Breakdown PSC1-C-10-SDM1-FB2 =
• PSC1: Base Unit
• C: 24V DC
• 10: 10 Inputs
• SDM1: Safety Door Monitor
• FB2: Enhanced Function Block
Safety Standards EN ISO 13849-1, EN IEC 62061, IEC 61508
Performance Level (PL) PL e (Category 4)
Safety Integrity Level SIL 3 (IEC 62061/61508)
Core Functionality Integrated safety door monitoring + muting/locking logic
Input Channels 10 Smart Inputs:
• 4x Door position (OSSD/contact)
• 2x Lock status
• 2x Muting sensors
• 2x External commands (E-stop/reset)
Output Channels 6 Safety Outputs:
• 2x Force-guided relays (5A @ 230V AC)
• 2x Lock control (2A @ 24V DC)
• 1x Muting lamp
• 1x Semiconductor status
Hybrid Logic Features SDM1 + FB2 Combined:
• Multi-door sequencing
• Guard locking w/ position verify
• Muting sequences (ISO 13855)
• Time-delayed unlocking (0–600s)
• Cross-zone access control
Voltage Supply 24V DC (20.4–28.8V DC)
Power Consumption ≤ 8W (max with active loads)
Response Times • 35 ms (door status)
• 100 ms (muting)
• 200 ms (lock release)
Safety Functions • Door position monitoring
• Lock engagement verification
• Material flow muting
• Restart interlock
• Standstill detection
Diagnostic Capabilities • Per-function status LEDs
• Event logging (20 faults)
• Real-time muting counter
• Lock cycle monitoring
Enclosure Rating IP20 (Control cabinet)
Mounting DIN-rail (35mm)
Operating Temperature -10°C to +55°C
Connection Type Spring-cage terminals (1.5 mm²)
Certifications CE, UL 508, TÜV Nord, UKCA, EAC
Status Indicators • RGB system status LED
• Door/lock/muting icons
• Input/output state lights
Key Innovations • Simultaneous door/muting control
• Dynamic zone locking
• Machine state-based unlocking
Compatible Devices PSENcode, PSENmlock, SD series, PSENopt muting sensors
Typical Applications Automotive body shops, food processing lines, robotic palletizing systems

 

 

 

 

 

 

 

 

Packaging & Shipping

 

PSC1-C-10-SDM1-FB2 10A Single Contact Interlock IP67 SS Modular Heavy Duty Flange Guard 0

 

Company Information
Xiamen ZhiCheng Automation Technology Co., Ltdit is a leading global supplier of control system components. We specialize in control systems and drives.


With many years of experience in the industrial sector, we consistently deliver the highest quality of spare parts.which make sure that all this jobs are

 

perfectly.

 

PSC1-C-10-SDM1-FB2 10A Single Contact Interlock IP67 SS Modular Heavy Duty Flange Guard 1

 

we are major in PLC,Sensors,HIM,Transmitters.


Best Supply Brands As Following:1)Bently nevada.2)+GF+.3)Rosemount.4)ABB.5)Allen-Bradley.6)Foxobro.Good working environment, perfect team, sincere cooperation →→ Achieve u and our success !!!

 

PSC1-C-10-SDM1-FB2 10A Single Contact Interlock IP67 SS Modular Heavy Duty Flange Guard 2